Solutions of GI-T Steel Turn Black with Phosphating
TIAN Yun-feng[1];YUAN Hong-li[1];RAN Hao[1]
Author information+
[1]Great Wall Automobile Co.,Ltd.,Hebei Province Automobile Technology Innovation Center,Baoding 071000,Hebei,China
Show less
History+
Published
2022-03-29
Issue Date
2022-03-29
Abstract
This article mainly focuses on the problem of phosphating blackening after the application of a certain automobile T-treated steel plate.Through the microscopic analysis of the surface of the phosphating film,and based on the inspection results of the phosphating tank circulation pipeline,it is determined that it is due to the circulation pipe.It is caused by road blockage,which provides guidance and suggestions for solving the problem of T-treated steel plate in the coating and phosphating process.